About this policy
CMS NCA document | source_status=Closed | review_type=1st Recon | public_comment_open=False | document_id=CAG-00399R
Coverage indications
CMS received a request to delete the national noncoverage of blood flow measurement from the Magnetic Resonance Imaging NCD at 220.2 of the NCD Manual and thus permit local Medicare contractor discretion to cover this use under 220.2(D). The requestor points to an apparent contradiction between this noncoverage provision and the national coverage of magnetic resonance imaging under the Magnetic Resonance Angiography NCD at 220.3 of the NCD Manual. CMS also received a separate request to revise the reference to cardiac pacemakers to permit coverage for MRI when a beneficiary has an implanted device that has been designed, tested and FDA labeled for use in the MRI environment. NCD 220.2 currently includes the following: The MRI is not covered when the following patient-specific contraindications are present. It is not covered for patients with cardiac pacemakers or with metallic clips on vascular aneurysms. We have considered both requests in this reconsideration. CMS finds that the blanket noncoverage of MRI for blood flow determination at 220.2 is no longer supported by the available evidence. Therefore we will remove the phrase "blood flow measurement," from the Nationally Noncovered Indications at 220.2(C)(2) of the National Coverage Determinations Manual. Pursuant to 220.2(D), local Medicare contractors will have discretion to cover (or not cover) this use. CMS has not found evidence that MRI improves health outcomes in beneficiaries who have an implanted cardioverter-defibrillator or cardiac pacemaker approved by FDA for use in an MRI environment. We also note that there are currently no such devices. Therefore we will not change this provision of the NCD Manual. We will retain the current contraindications.
Documentation requirements
Decision Memo: To: Administrative File: CAG # 00399R Magnetic Resonance Imaging From: Tamara Syrek Jensen, JD Acting Director, Coverage and Analysis Group Louis B. Jacques, MD Division Director Kimberly Long Lead Analyst Brijet Burton, PA-C, MS Analyst Ross Brechner, MD, MS (Stat.), MPH Lead Medical Officer Subject: Final Decision Memorandum for CAG # 00399R Magnetic Resonance Imaging Date: September 28, 2009 I. Final Decision CMS received a request to delete the national noncoverage of blood flow measurement from the Magnetic Resonance Imaging NCD at 220.2 of the NCD Manual and thus permit local Medicare contractor discretion to cover this use under 220.2(D). The requestor points to an apparent contradiction between this noncoverage provision and the national coverage of magnetic resonance imaging under the Magnetic Resonance Angiography NCD at 220.3 of the NCD Manual. CMS also received a separate request to revise the reference to cardiac pacemakers to permit coverage for MRI when a beneficiary has an implanted device that has been designed, tested and FDA labeled for use in the MRI environment. NCD 220.2 currently includes the following: The MRI is not covered when the following patient-specific contraindications are present. It is not covered for patients with cardiac pacemakers or with metallic clips on vascular aneurysms. We have considered both requests in this reconsideration. CMS finds that the blanket noncoverage of MRI for blood flow determination at 220.2 is no longer supported by the available evidence. Therefore we will remove the phrase "blood flow measurement," from the Nationally Noncovered Indications at 220.2(C)(2) of the National Coverage Determinations Manual. Pursuant to 220.2(D), local Medicare contractors will have discretion to cover (or not cover) this use. CMS has not found evidence that MRI improves health outcomes in beneficiaries who have an implanted cardioverter-defibrillator or cardiac pacemaker approved by FDA for use in an MRI environment. We also note that there are currently no such devices. Therefore we will not change this provision of the NCD Manual. We will retain the current contraindications. II. Background Magnetic resonance imaging (MRI, formerly known as nuclear magnetic resonance imaging - NMRI) is a noninvasive method of graphically representing the distribution of water and other hydrogen-rich molecules in the human body. Magnetic resonance imaging is a diagnostic imaging modality that is capable of demonstrating a wide variety of soft-tissue lesions with contrast resolution equal or superior to CT scanning in various parts of the body. Among the advantages of MRI are the absence of ionizing radiation and the ability to achieve high levels of tissue contrast resolution without injected iodinated radiological contrast agents. The terms CMR and CMRI refer respectively to cardiac magnetic resonance and cardiac MRI. We provide a very simplified discussion below for the lay reader. Systole describes the period during which the right and left cardiac ventricles contract forcefully and eject blood into the pulmonary artery and the aorta respectively. Diastole describes the period during which the relaxed ventricles fill with blood. There are four cardiac valves in the normal human heart. During diastole blood in the right atrium flows through the tricuspid valve into the right ventricle and blood in the left atrium flows through the mitral valve into the left ventricle. During systole blood in the right ventricle flows through the pulmonic valve into the pulmonary artery and blood in the left ventricle flows through the aortic valve into the aorta. The following terms refer to abnormal function of cardiac valves: AS = aortic stenosis; AR = aortic regurgitation; MS = mitral stenosis; MR = mitral regurgitation. Stenosis indicates a narrowing of the valve opening and regurgitation indicates backflow of blood through a valve that fails to close completely. Either condition may lead to deterioration of cardiac function. Valvular dysfunction may arise from a variety of causes such as heritable conditions, infections, rheumatic disease, ischemia and degenerative calcification. Many diagnostic modalities may contribute to a diagnosis of valvular disease. Physical examination, electrocardiography (EKG), echocardiography, plain X-rays or more complex imaging, and catheterization have been used. Valvular abnormalities may be visualized directly, i.e. by the identification of abnormal anatomic structure or a reduced cross sectional area of the valve’s opening, or indirectly via measurement of the speed (velocity) and volume of blood flow through the opening. Medical and/or surgical treatments may be recommended depending on the underlying cause and the severity of the dysfunction. A detailed discussion of the pathophysiology and treatment of specific valvular conditions is beyond the scope of this memorandum. Magnetic resonance imaging exposes the patient to strong magnetic fields which may cause the movement or heating of implanted medical devices that are ferromagnetic (e.g. surgical clips) or that have ferromagnetic components (e.g. pacemakers, prostheses.) Such movement can have catastrophic effects on the patient. The American College of Radiology’s ACR Guidance Document for Safe MR Practices: 2007 explicitly speaks to the need to address the possibility that the patient may have ferromagnetic foreign bodies or implants. III. History of Medicare Coverage Section 220.2 of the NCD Manual speaks to coverage of MRI. CMS originally set forth the conditions under which MRI may be covered in November, 1985. Revisions to the policy took place in 1988, 1991, and 1994 to provide coverage for additional conditions. Currently covered indications include using MRI to examine the head, central nervous system, and spine. MRI can also assist in the differential diagnosis of mediastinal and retroperitoneal masses, including abnormalities of the large vessels such as aneurysms and dissection. MRI may also be used to detect and stage pelvic and retroperitoneal neoplasms and to evaluate disorders of cancellous bone and soft tissues. The MRI may also be covered to diagnose disc disease without regard to whether radiological imaging has been tried first to diagnose the problem. Blood flow measurement, imaging of cortical bone and calcifications, and procedures involving spatial resolution of bone and calcifications, are nationally non-covered indications. All other uses of MRI for which CMS has not specifically indicated are under local contractor discretion. The MRI is not covered when patient-specific contraindications such as cardiac pacemakers, metal clips on vascular aneurysms, viable pregnancy, acutely ill patients requiring life support systems and monitoring devices that employ ferromagnetic materials, or patients suffering from claustrophobia, are present. We note for the readers’ convenience that some uses of MRI related to blood flow are specifically determined in the Magnetic Resonance Angiography NCD at 220.3 of the NCD Manual. A. Current Request The requestors have asked CMS to reconsider Section 220.2 to remove the reference to blood flow measurement in the nationally non-covered indications. During the initial 30-day comment period, CMS received a request from Medtronic, Inc. to modify the Contraindications section to permit coverage of MRI when the beneficiary has an implanted device such as a cardiac pacemaker that has been designed, tested and FDA labeled for use in the MRI environment. B. Benefit Category Medicare is a defined benefit program. An item or service must fall within a benefit category as a prerequisite to Medicare coverage §1812 (Scope of Part A); §1832 (Scope of Part B) and §1861(s) (Definition of Medical and Other Health Services) of the Act. Magnetic resonance imaging is considered to be within the following benefit category: other diagnostic tests §1861(s)(3). This may not be an exhaustive list of all applicable Medicare benefit categories for this item or service. Medicare regulations at 42 CFR 410.32(a) state in part, that "…diagnostic tests must be ordered by the physician who is treating the beneficiary, that is, the physician who furnishes a consultation or treats a beneficiary for a specific medical problem and who uses the results in the management of the beneficiary’s specific medical problem." Thus, except where other uses have been explicitly authorized by statute, Medicare does not cover diagnostic testing used for routine screening or surveillance. IV. Timeline of Recent Activities Date Action January 20, 2009 CMS opens this reconsideration of the NCD on Magnetic Resonance Imaging (MRI). February 19, 2009 The initial 30 day public comment period ended. Eighty-six comments were received. March 16, 2009 During the initial 30-day comment period, CMS received a request from Medtronic, Inc. to modify the Contraindications section to permit coverage of MRI when devices such as cardiac pacemakers have been designed, tested and FDA labeled for use in the MRI environment. CMS solicits additional public comment for 30 days on this aspect of the request. Six comments were received. June 30, 2009 Proposed decision posted July 30, 2009 The 30-day public comment period ended. Eight comments were received. V. FDA Status The Food and Drug Administration (FDA) has approved or cleared magnetic resonance diagnostic devices from various manufacturers. A detailed enumeration of those devices is beyond the scope of this memorandum. At this time, FDA has not approved any implantable cardioverter-defibrillators or pacemakers for use in an MRI environment. VI. General Methodological Principles When making national coverage determinations, CMS evaluates relevant clinical evidence to determine whether or not the evidence is of sufficient quality to support a finding that an item or service falling within a benefit category is reasonable and necessary for the diagnosis or treatment of illness or injury or to improve the functioning of a malformed body member. The critical appraisal of the evidence enables us to determine to what degree we are confident that: 1) the specific assessment questions can be answered conclusively; and 2) the intervention will improve health outcomes for beneficiaries. An improved health outcome is one of several considerations in determining whether an item or service is reasonable and necessary. A detailed account of the methodological principles of study design that the Agency utilizes to assess the relevant literature on a therapeutic or diagnostic item or service for specific conditions can be found in Appendix A. Public commenters sometimes cite the published clinical evidence and provide CMS with useful information. Public comments that provide information based on unpublished evidence, such as the results of individual practitioners or patients, are less rigorous and, therefore, less useful for making a coverage determination. CMS uses the initial comment period to inform the public of its proposed decision. CMS responds in detail to the public comments that were received in response to the proposed decision when it issues the final decision memorandum. VII. Evidence A. Introduction Below is a summary of the evidence we considered during our review. The Medicare regulations at 42 CFR 410.32(a) state in part, that "…diagnostic tests must be ordered by the physician who is treating the beneficiary, that is, the physician who furnishes a consultation or treats a beneficiary for a specific medical problem and who uses the results in the management of the beneficiary’s specific medical problem." The original requestors did not ask for national Medicare coverage of MRI for the assessment of blood flow, but specifically requested the removal of the national noncoverage provision so that Medicare contractors could determine coverage for MRI claims without this broad national noncoverage provision. The requestors submitted evidence relating to the use of MRI to determine cardiac blood flow to support their request for removal of the blanket national noncoverage provision regarding blood flow. Thus, we reviewed evidence demonstrating that the MRI assessment of cardiac blood flow can be used in the management of a Medicare beneficiary’s medical problem and improves patient outcomes. We did not review evidence that was focused on pediatric study populations, as it is not generalizeable to the Medicare beneficiary population. We did not review evidence that focused on technologic feasibility in normal subjects as these data do not speak to the outcomes attributable to the use of MRI for the management of disease. We did not find evidence suggesting any disparate effect of this technology on historically underserved populations. We have for the readers’ reference included all of the requestors’ submitted articles in Appendix B. The secondary requestor (Medtronic) did not ask for national Medicare coverage of any particular use of MRI, but specifically requested the removal of the national noncoverage provision containing the contraindication related to implanted devices such as pacemakers. Thus, we looked for evidence demonstrating that MRI assessment in a beneficiary with an implanted pacemaker of cardioverter-defibrillator improves patient health outcomes. B. Discussion of Evidence Reviewed 1. Questions The original request Q1. Is the evidence adequate to conclude that MRI assessment of cardiac blood flow informs the diagnosis of cardiac valvular, cardiac shunt, cardiac stroke and ejection volume pathologies, compared to diagnosis of these conditions without MRI assessment of cardiac blood flow? Q2. Is the evidence adequate to conclude that the MRI assessment of cardiac blood flow improves health outcomes in patients who have valvular pathology, intracardiac shunts, stroke volume abnormalities or reduced ejection fraction? The secondary request Q3. Is the evidence adequate to conclude that MRI improves health outcomes in Medicare beneficiaries who have implanted devices such as pacemakers or implantable cardioverter-defibrillators that have been approved by FDA as safe for use in an MRI environment? 2. External Technology Assessments CMS did not request an external technology assessment (TA) on this issue from the Agency for Healthcare Research and Quality (AHRQ). 3. Internal technology assessment The original request The reviewed evidence was gathered from articles submitted by the original requestor and a literature search of the PubMed database. CMS performed an extensive literature search utilizing PubMed for search terms involving MRI and cardiac blood flow. Summaries are provided below, organized by year in reverse chronologic order. Please see the evidence tables for additional details about the characteristics of the study subjects. The evidence included comparisons of MRI with other diagnostic technologies as well as studies where MRI was used to assess the results of alternative cardiac treatment strategies. Tanaka et al. (2007) The authors sought to assess whether velocity-encoded phase-contrast MRI can provide an alternate means of quantifying aortic valve area (AVA) by CMRI. Twenty-two consecutive AS patients were imaged with CMRI. AVA was determined by velocity-encoded phase contrast (VEPC) imaging and by direct planimetry. Mean AVA by planimetry was 1.05± 0.41 cm 2 and 1.00± 0.4 cm 2 by VEPC, with a strong correlation (R 2 = 0.86, p < 0.0001) between the two methods. The mean difference of AVA was 0.05± 0.15 (95% CI = [0.02-0.08]), and the limits of agreement were -0.26 to 0.36 cm 2 . The mean difference between 2 observers for planimetry was 0.030± 0.07 (95% CI 0.02-0.04) with limits of agreement of -0.11 to 0.16 cm 2 and for VEPC was 0.008± 0.085 (95% CI -0.01-0.026) with limits of agreement of -0.16 to 0.18 cm 2 . The authors concluded that VEPC CMRI is an alternative method to direct planimetry for accurately determining AVA. Yap et al. (2007) The authors aimed to compare velocity-encoded cine cardiac magnetic resonance (CMR) with an established echocardiographic method for noninvasive measurement of aortic valve area (AVA) using the continuity equation. Twenty consecutive young adults with stenotic bicuspid aortic valves were examined with CMR and transthoracic echocardiography (TTE). CMR AVA was calculated by the continuity equation, dividing stroke volume by the aortic velocity-time integral (VTIAorta), the stroke volume measured both by ventricular volume analysis and by phase contrast velocity mapping at 4 levels (1 subvalvar and 3 supravalvar). Stroke volumes measured at all levels correlated well with those from volumetric analysis. The CMR AVAs calculated using volumetric analysis and VTIAorta from jet velocity mapping correlated and agreed well with TTE AVA measurements (R 2 = 0.83). When CMR AVA was calculated more rapidly using volume flow and VTIAorta both measured from the same trans-jet velocity acquisition, R2 was 0.74, with a bias and limits of agreement of 0.02 (-0.44, 0.47) cm 2 . The authors concluded that continuity equation calculation of the AVA using CMR velocity mapping, with or without ventricular volumetric measurement, correlated and agreed well with the comparable and widely accepted TTE approach. Gelfand et al. (2006) The investigators sought to define the CMR regurgitant fractions that best correlate with qualitative mild, moderate, and severe regurgitation by color Doppler echocardiography. Data from 141 consecutive patients (age 53 ± 15 yr; 43% female) with contemporary (median, 31 days) CMR and echocardiographic data, including 107 regurgitant valves and 70 normal valves, were compared. Thresholds were developed on an initial cohort of patients with 55 regurgitant valves, and subsequently tested on a later cohort of patients with 52 regurgitant valves. Regurgitation fraction (RF) limits that optimized concordance of CMR and echo severity grades were similar for MR (mitral regurgitation) and AR (aortic regurgitation) and were: mild ± 15%, moderate 16-25%, moderate-severe 26-48%, severe > 48%. The authors concluded that their study provided simple qualitative threshold grades for MR and AR severity that allows for standardized reporting of regurgitation severity by CMR and excellent correlation with clinical echocardiography. Paelnick et al. (2005) The aim of this study was to compare tissue magnetic resonance (MR) imaging with tissue Doppler imaging for the estimation of filling pressure, in comparison with invasive measurement. The authors state that transmitral flow is unreliable for the estimation of left ventricular (LV) filling pressures in hypertrophy and normal systolic function. They further state that normalizing early mitral velocity (E) for the influence of myocardial relaxation by combining E with early diastolic mitral septal tissue velocity (Ea) provides better Doppler estimates of filling pressures. The authors studied 18 persons with hypertensive heart disease (LV mass index: 114 ± 21 g/m 2 ), absence of valvular regurgitation, and with normal or mildly reduced systolic function (LV ejection fraction: 57.6 ± 6.5%) referred for cardiac catheterization. They all underwent consecutive measurement of mitral flow and septal tissue velocities with phase-contrast MR and Doppler. These data were compared with mean pulmonary capillary wedge pressure (PCWP). There was a strong relation between MR (11.6 ± 4.3) and Doppler-assessed (12.1 ± 3.5) E/Ea (95% confidence interval of -1.5 to 0.5) (r = 0.89, p < 0.0001). In addition, E/Ea related strongly to invasively measured PCWP (MR: r = 0.80, p < 0.0001 and Doppler: r = 0.85, p < 0.0001). The authors concluded that tissue MR imaging is a feasible method to assess Ea and that combining E and Ea allowed similar estimation of filling pressure by MR and Doppler, in good agreement with invasive measurement. Malm et al. (2005) The authors aimed to evaluate whether the use of apical long-axis (APLAX) rather than two-chamber (2CH) view, in combination with four-chamber (4CH) view, improved accuracy of biplane echocardiographic measurements of left ventricular (LV) ejection fraction (EF), using magnetic resonance imaging (MRI) as a reference standard. One hundred consecutive cardiac patients underwent cardiac MRI and 2D-echocardiography. Standard apical LV views were digitally acquired with baseline tissue harmonic imaging and low-power contrast echocardiography. Echocardiographic and MRI LV volumes were calculated by manual tracing and disc summation methods. Feasibility for biplane volume measurements increased with the use of APLAX. Precontrast limits of agreement (LOA) for EF compared to MRI were -19.1 to 9.0 % (EF units) using 2CH, narrowing to -14.6 to 6.7% using the APLAX. With contrast, corresponding LOAs narrowed from -10.5 to 6.1%, to -7.3 to 3.8%, respectively. The improved accuracy with APLAX was evident regardless of image quality, previous MI and regional LV dyssynergy. Both intra- and interobserver variability improved by substituting 2CH with APLAX view. Using APLAX rather than 2CH in combination with 4CH view improved feasibility, accuracy and reproducibility of biplane echocardiographic EF measurements in cardiac patients, even with optimization of endocardial borders by contrast, all using CMRI as a reference standard. Lim et al. (2005) This study aimed to evaluate the accuracy of low-power contrast echocardiography (CE) to assess LV remodeling after AMI compared with unenhanced harmonic echocardiography (HE). A total of 36 consecutive patients underwent HE, CE (SonoVue), and cardiovascular magnetic resonance (CMR) imaging 7 to 10 days after AMI. Left ventricular ejection fraction (LVEF), endsystolic volume (LVESV), and end-diastolic volume (LVEDV) were assessed. Absolute differences for LVESV and LVEDV between CMR and CE were significantly smaller than those between CMR and HE. CE estimate of LVEF more accurately classified patients into LVEF < 35%, 35% to 45%, and > 45% (agreement, 83%; kappa = 0.66 with CMR) compared with HE (agreement, 69%; kappa = 0.33 with CMR). The authors concluded that low-power CE is more accurate than HE for estimating LV remodeling after AMI, using CMR as a reference standard. Westenberg et al. (2005) In this study, authors sought to quantify the exact flow through the mitral valve with a 3-directional velocity-encoded MRI approach. Ten patients with severe mitral valve regurgitation (class 3-4+ with echocardiography) resulting from systolic restrictive motion of both leaflets (Carpentier IIIb) which were selected for valve repair and 10 healthy volunteers without cardiac valvular disease confirmed with echocardiography were included in this study. The intra-ventricular flow was sampled with a radial stack of six acquisition planes parallel to the long-axis of the left ventricle. Three-directional velocity-encoded MRI was performed resulting in the intra-ventricular flow velocity vector field for 30 phases during the cardiac cycle. The position of the mitral valvular plane in this vector field was indicated manually for each phase. Velocity values perpendicular to this plane determined the flow through the mitral valve. Both the 3-directional encoded mitral valve flow and the 1-directional encoded mitral valve flow were compared with the flow determined with MRI at the ascending aorta. One-directional velocity-encoded MRI showed a mean overestimation (P < 0.01) of 25 ml/cycle compared to the aortic flow. Correlation was very poor (r(P) = 0.15, P = 0.68). The 3-directional velocity-encoded MRI on the other hand, showed no over/underestimation and a good correlation (r(P) = 0.91, P < 0.01 for volunteers, r(P) = 0.90, P < 0.01 for patients). The regurgitant flow fractions were between 3 and 30%. The authors concluded that with 3-directional velocity-encoded MRI, measurement of the flow through the mitral valve is accurate and reproducible. Grothues et al. (2004) The authors sought to determine the interstudy reproducibility of measurements of right ventricular (RV) volumes, function, and mass with CMRI and compare it with correspondent LV values. Sixty subjects (47 men; 20 healthy volunteers, 20 patients with heart failure, 20 patients with ventricular hypertrophy) underwent 2 CMRI studies for assessment of RV measurements with a minimum time interval between each study. The overall interstudy reproducibility (range between groups) for the RV was 6.2% (4.2%-7.8%) for end-diastolic volume, 14.1% (8.1%-18.1%) for end-systolic volume, 8.3% (4.3%-10.4%) for ejection fraction (EF), and 8.7% (7.8%-9.4%) for RV mass. RV reproducibility was not as good as for the LV for all measures in all 3 groups, but this was only statistically significant for EF (P < .01). The authors concluded that CMRI showed good interstudy reproducibility for RV function parameters in healthy subjects, patients with heart failure, and patients with hypertrophy, which suggests that CMRI is reliable for serial RV assessment. Lin et al. (2004) The purpose of this study was to evaluate the reliability of the pressure half-time (PHT) method for estimating mitral valve areas (MVAs) by velocity-encoded cardiovascular magnetic resonance (VE-CMR) and to compare the method with paired Doppler ultrasound. Seventeen patients with mitral stenosis underwent echocardiography and CMR. Using VE-CMR, MVA was estimated by PHT method. Additionally, peak E and peak A velocities were defined. Interobserver repeatability of VE-CMR was evaluated. By Doppler, MVAs ranged from 0.87 to 4.49 cm 2 ; by CMR, 0.91 to 2.70 cm 2 correlating well between modalities (r = 0.86). The correlation coefficient for peak E and peak A between modalities was 0.81 and 0.89, respectively. Velocity-encoded CMR data analysis provided robust, repeatable estimates of peak E, peak A, and MVA (r = 0.99, 0.99, and 0.96, respectively). The authors concluded that velocity-encoded cardiovascular magnetic resonance can be used routinely as a robust tool to quantify MVA via mitral flow velocity analysis with PHT method. Li et al. (2003) The purpose of this study was to compare the noninvasive assessment of severity of pulmonary regurgitation with Doppler echocardiography versus cardiovascular magnetic resonance imaging (CMR) in adult patients with repaired tetralogy of Fallot (rTOF). The authors studied 52 (22 females) consecutive patients (aged 32 ± 2 years, 23 ± 5 years after rTOF) using Doppler echocardiography and compared these findings with CMR. From the continuous-wave Doppler trace, the duration of pulmonary regurgitation and of total diastole was measured and the ratio between the 2 was defined as pulmonary regurgitation index (PRi). Pulmonary regurgitant fraction (PRF) was assessed with flow phase velocity mapping with CMR. Patients were divided into 2 groups according to the median value (24.5%) of PRF measured by CMR: Group I (26 patients) with PRF ± 24.5% and Group II with PRF > 24.5%. There was no difference between patients' age, sex, or age at repair between the 2 groups. More patients from Group II had a right ventricular outflow or transannular patch repair compared to Group I (12/26 [46%] versus 6/26 [23%], P < .01). Mean pulmonary regurgitation time was shorter (340 ± 60 versus 440 ± 135 ms, P = .001) and PRi was lower (0.61 ± 0.11versus0.91 ± 0.11, P < .001) in Group II compared to Group I. Color Doppler regurgitant jet was also broader in Group II (1.4 ± 0.4 versus 0.7 ± 0.5 cm, P < .001), signifying more severe pulmonary regurgitation. Doppler-measured PRi correlated closely with CMR regurgitant fraction (r = -0.82, P < .001) and with color Doppler pulmonary regurgitant jet width (r = -0.66, P < .001); the latter correlated with PRF assessed with CMR (r = 0.72, P < .001). A PRi < 0.77 had 100% sensitivity and 84.6% specificity for identifying patients with pulmonary regurgitant fraction > 24.5%, with a predictive accuracy of 95%. Furthermore, echocardiographically-assessed right ventricular end-diastolic dimensions correlated with CMR end-diastolic volume index (r = 0.49, P < .001). The authors concluded that the severity of pulmonary regurgitation and its effects on right ventricular dimensions in these patients can be assessed noninvasively by Doppler echocardiography and CMR, with reasonable agreement between the 2 techniques. Powell et al. (2003) The aim of this study was to prospectively evaluate the accuracy, reproducibility, and interobserver variability of phase-velocity cine magnetic resonance imaging (PVC MRI) measurements of Qp/Qs in subjects with a known shunt. Oximetry at catheterization was selected for comparison because, according to the authors, this remains the most widely accepted clinical standard [as of the date of the study]. From June 1999 to March 2002, 20 subjects were prospectively enrolled in the study (12 female and 8 male subjects, mean age 27± 13 years [range 9 to 52]). No subject had significant cardiac disease other than a secundum atrial septal defect or patent foramen ovale. All subjects completed the MRI protocol without complications and underwent cardiac catheterization within a median of 2 days (range 0 to 32). The authors concluded that this study prospectively demonstrated close agreement between PVC MRI and invasive oximetry measurements of Qp/Qs in 20 patients with interatrial communications. Caruthers et al. (2003) The purposes of this study were to define the reliability of velocity-encoded CMR as a routine method for quantifying stenotic aortic valve area, to compare this method with the accepted standard, and to evaluate its reproducibility. Patients (n = 24) with aortic stenosis (ranging from 0.5 to 1.8 cm2) were imaged with CMR and echocardiography. Velocity-encoded CMR was used to obtain velocity information in the aorta and left ventricular outflow tract. From this flow data, pressure gradients were estimated by means of the modified Bernoulli equation, and VTIs were calculated to estimate aortic valve orifice dimensions by means of the continuity equation. The correlation coefficients between modalities for pressure gradients were r = 0.83 for peak and r = 0.87 for mean. The measurements of VTI correlated well, leading to an overall strong correlation between echocardiography and MRI modalities for the estimation of valve dimension (r = 0.83). For 5 subjects, the CMR examination was repeated using the best approach. The repeat calculations of valve size correlated well (r = 0.94). The authors concluded that velocity-encoded CMR can be used as a reliable, user-friendly tool to evaluate stenotic aortic valves. The measurements of pressure gradients, VTIs, and the valve dimension correlate well with the accepted standard of Doppler ultrasound. Nanda et al. (2003) This study was conducted to assess the ability of a new echocardiographic contrast agent, Imagent (perflexane lipid microspheres; to improve endocardial border delineation (EBD) and assessment of segmental wall motion (SWM). This was achieved by analysis of inter-reader agreement by echocardiography and comparison with an independent imaging technique, magnetic resonance imaging (MRI). Two separate, independent, prospective, randomized, controlled, multicenter trials were conducted at 26 centers and included a total of 409 efficacy-evaluable patients. In Study A 206 patients were randomized to receive either Imagent or saline and in Study B, 203 patients received Imagent with a subset of 26 of 203 patients imaged by both echocardiography and MRI. Patients were referred for echocardiograms for a range of indications including the assessment of regional and global LV function. All patients were required to have suboptimal baseline images using fundamental imaging. Imagent, a suspension of perfluorohexane-filled spheres with flexible lipid shells, was administered as an IV bolus at 0.125 mg/kg body weight. Gated MRI studies were performed within 48 hours of dosing in the subset of 26 subjects. For comparison to MRI, the results from echo readers 4, 5, and 6 were each compared with a single independent MRI reader. Blinded review of the noncontrast echo examinations resulted in agreement with MRI derived SWM scores in 15% of the segments. The administration of Imagent improved this agreement to 47%, of the segments (P ≤ 0.0005 for each blinded reader). Use of Imagent during echocardiographic imaging improves EBD, providing a significant improvement in inter-reader agreement in SWM evaluation with echo and greater than a threefold improvement in SWM scoring accuracy with MRI. This study (B) has severe design drawbacks and is not really an RCT. No separate information for the 26 patients selected for MRI re: demographics, method of selection, etc, was given. The authors also state that MRI has become an alternative method for the assessment of wall motion, proving particularly beneficial in patients where suboptimal image quality is obtained during echocardiographic assessment. Grothues et al. (2002) The authors aimed to make a direct comparison of the interstudy reproducibility of both CMRI and echocardiography methods in the same subjects. A total of 60 subjects (normal volunteers [n = 0], or patients with heart failure [n = 20] or LV hypertrophy [n = 20]) underwent 2 CMRs and 2 echocardiographic studies for assessment of LV volumes, function, and mass. The interstudy reproducibility coefficient of variability was superior for CMR in all groups for all parameters. The authors concluded that statistical significance was reached for end-systolic volume (4.4% to 9.2% versus 13.7% to 20.3%, p < 0.001), ejection fraction. Aaberg (2001) One hundred patients with refractory angina were randomized 1:1 to TMR (CO2 laser) and medical treatment, or medical treatment alone. Technetium 99m (99mTc)-tetrofosmin myocardial perfusion tomography (SPECT), quantitative myocardial perfusion gated SPECT (QGSPECT), technetium 99m (99mTc) multiple gated acquisition radionuclide ventriculography (MUGA) and cine-magnetic resonance imaging (cine-MRI) were performed at baseline and after 3 and 12 months. Following TMR, a slight reduction in left ventricular ejection fraction (LVEF) (p < 0.05) was observed (MUGA and QGSPECT) compared to baseline. Inclusion of incomplete studies (QGSPECT) revealed a significant reduction in LVEF and increase in left ventricular end-diastolic volume (LVEDV) (p < 0.05) compared to a control group. Otherwise, no between-group comparisons showed statistically significant differences. The authors concluded that TMR did not improve myocardial perfusion, but led to a reduction in LVEF and increase in LVEDV, however not significantly different from the control group. Arheden et al. (1999) The authors aimed at investigating the agreement between two noninvasive methods, magnetic resonance (MR) velocity mapping and first-pass radionuclide angiography, to quantify the pulmonary-to-systemic blood flow ratio (QP/QS) in adults, adolescents, and children with left-to-right cardiac shunts. The accuracy and precision of MR velocity mapping were studied in 12 control subjects (six men, six women) and in a phantom. MR velocity mapping and radionuclide angiography were performed on the same day in 24 patients (16 adults, two adolescents, six children; five male patients, 19 female patients). The mean error in QP/QS at MR velocity mapping in phantom experiments was -1% ± 1 (mean ± SD). In control subjects, QP/QS at MR velocity mapping was 1.03 ± 0.03, and the cardiac index was 3.1 L/min/m 2 ± 0.2 and 3.2 L/min/m 2 ± 0.3 for women and men, respectively. In patients, QP/QS at radionuclide angiography was 14% ± 13, higher than at MR velocity mapping. Interobserver variability was four times higher for radionuclide angiography compared with MR velocity mapping, 0% + 16 versus 0% ± 4 (n = 12). The difference between repeated MR flow measurements in the same vessel was -1% ± 5 (n = 36). The authors concluded that the data suggested that MR velocity mapping is accurate and precise for measurements of shunt size over the whole range of possible QP/QS values. Berg (1998) To compare the effects of stented and stentless prostheses on early hemodynamic function and late left ventricular mass regression, a prospective randomized clinical trial was conducted. Following valve sizing, 20 patients were randomized to receive a Carpentier-Edwards SAV stented bioprosthesis (mean annular size-25.3 mm, mean valve size-23 mm) of which eight also had bypass grafts. Twenty patients were randomized to receive a Toronto Stentless Porcine Valve (SPV), mean annular size-25.5 mm, mean valve size-26 mm, of which nine had bypass grafts. The stentless valve group had a longer ischemic time (77.9 ± 20.9 min versus 60.9 ± 21.9 min) and bypass time (101.7 ± 27.1 min versus 82.9 ± 20.2 min). Using continuous cardiac output monitoring, no statistically significant differences were found in early hemodynamic indices although the stentless group required less inotropes and had a shorter ventilation time (16.1 ± 4.2 hrs versus 55.2 ± 104.9 hrs) and intensive care stay (1.1 ± 0.2 days versus 4.6 ± 8.3 days). Mean and peak aortic gradients one week postoperatively were lower in the stentless group (5.6 ± 3 mmHg versus 8.9 ± 2.3 mmHg and 12.5 ± 7.8 mmHg versus 24.4 ± 8.8 mmHg respectively). CMRI at one week and six months was used to measure stroke volumes, ejection fractions, end diastolic muscle mass and end systolic muscle mass indices. CMRI showed a 15% reduction in the end systolic muscle mass index in the stented group but a greater reduction of 29% in the stentless group. The authors concluded that this study showed that despite requiring a more demanding technique of insertion, aortic valve replacement with the Toronto stentless porcine valve can produce satisfactory early clinical results. In this study CMRI was the standard for measurement of stroke volumes, ejection fractions, end diastolic muscle mass and end systolic muscle mass indices and was not compared to any other modality Hundley et al. (1995b) Velocity-encoded, phase-difference magnetic resonance imaging (MRI) has been used to measure flow in the aorta, as well as in the pulmonary, carotid, and renal arteries, and the authors noted that these measurements have not [to present] been validated against currently accepted invasive techniques. To determine the accuracy of velocity-encoded, phase-difference MRI measurements of cardiac output, 23 subjects (11 men and 12 women, aged 15 to 72 years) underwent velocity-encoded, phase-difference MRI measurements of cardiac output in the proximal aorta, followed immediately by cardiac catheterization, with measurement of cardiac output by the Fick principle and by thermodilution. For MRI, Fick, and thermodilution measurements, stroke volume was calculated by dividing cardiac output by heart rate. The magnetic resonance images were acquired in 1 to 3 minutes. For all patients, the agreement between measurements of stroke volume was 3 ± 9 ml for MRI and Fick, -3 ± 11 ml for MRI and thermodilution, and 0 ± 8 ml for MRI and the average of Fick and thermodilution. The authors concluded that compared with standard invasive measurements, velocity-encoded, phase-difference MRI can accurately and rapidly determine cardiac output. Hundley et al. (1995a) This study was done to determine whether MRI can reliably measure the magnitude of mitral regurgitation and evaluate the effect of regurgitation on left ventricular volumes and systolic function. The authors noted that, in the patient with mitral regurgitation who is being considered for valvular surgery, cardiac catheterization is usually performed to quantify the severity of regurgitation and to determine its influence on left ventricular volumes and systolic function. They also noted that magnetic resonance imaging (MRI) potentially provides a rapid, noninvasive method of acquiring these data. Twenty-three subjects (14 women and 9 men 15 to 72 years of age) with (n = 17) or without (n = 6) mitral regurgitation underwent MRI scanning followed immediately by cardiac catheterization. The presence (or absence) of valvular regurgitation was determined, and left ventricular volumes and regurgitant fraction were quantified during each procedure. There was excellent correlation between invasive and MRI assessments of left ventricular end-diastolic (r = .95) and end-systolic (r = .95) volumes and regurgitant fraction (r = .96). All MRI examinations were completed in < 28 minutes. The authors concluded that, in the patient with mitral regurgitation, MRI compares favorably with cardiac catheterization for assessment of the magnitude of regurgitation and its influence on left ventricular volumes and systolic function. Heidenreich et al. (1995) The authors wrote that velocity-encoded cine-magnetic resonance imaging (VEC-MRI) was a new method for quantitation of blood flow with the potential to measure high-velocity jets across stenotic valves. The objective of their study was to evaluate the ability of VEC-MRI to measure transmitral velocity in patients with mitral stenosis. Sixteen patients with known mitral stenosis were studied. A 1.5 Tesla superconducting magnet was used to obtain velocity-encoded images in the left ventricular short-axis plane. Images were obtained throughout the cardiac cycle at 3 consecutive slices beginning proximal to the mitral coaptation point. To determine the optimal slice thickness for MRI imaging, both 10 mm and 5 mm thicknesses were used. Echocardiography including continuous-wave Doppler was performed on every patient within 2 hours of MRI imaging. Peak velocity was determined for both VEC-MRI and Doppler-echo images. Two observers independently measured the VEC-MRI mitral inflow velocities. Of the 16 patients, imaged data were incomplete in only 1 study, and all images were adequate for analysis. Strong correlations were found for measurements of mitral valve gradient for both 10 mm (peak r = 0.89, mean r = 0.84) and 5 mm (peak r = 0.82, mean r = 0.95) slice thicknesses. Measurements of peak velocity with VEC-MRI (10 mm) agreed well with Doppler: mean 1.46 m/s, mean of differences (Doppler MRI) 0.38 m/s, standard deviation of differences 0.2 m/s. The authors concluded that their findings suggested that VEC-MRI can noninvasively determine the severity of mitral stenosis. Fujita et al. (1994) The authors evaluated the feasibility of velocity-encoded cine nuclear magnetic resonance (NMR) imaging to measure regurgitant volume and regurgitant fraction in patients with mitral regurgitation. They hypothesized that the difference between mitral inflow and aortic systolic flow provides the regurgitant volume in the setting of mitral regurgitation. Using velocity-encoded cine NMR imaging at a magnet field strength of 1.5 T and color Doppler echocardiography, 19 patients with isolated mitral regurgitation and 10 normal subjects were studied. Velocity-encoded cine NMR images were acquired in the short-axis plane of the ascending aorta and from the short-axis plane of the left ventricle at the level of the mitral annulus. Two independent observers measured the ascending aortic flow volume and left ventricular inflow volume to calculate the regurgitant volume as the difference between left ventricular inflow volume and aortic flow volume, and the regurgitant fraction was calculated. Using accepted criteria of color flow Doppler imaging and spectral analysis, the severity of mitral regurgitation was qualitatively graded as mild, moderate or severe and compared with regurgitant volume and regurgitant fraction, as determined by velocity-encoded cine NMR imaging. In normal subjects the regurgitant volume was -6 ± 345 ml/min (mean ± SD). In patients with mild, moderate and severe mitral regurgitation, the regurgitant volume was 156 ± 203, 1,384 ± 437 and 4,763 ± 2,449 ml/min, respectively. In normal subjects the regurgitant fraction was 0.7 ± 6.1%. In patients with mild, moderate and severe mitral regurgitation, the regurgitant fraction was 3.1 ± 3.4%, 24.5 ± 8.9% and 48.6 ± 7.6%, respectively. The regurgitant fraction correlated well with the echocardiographic severity of mitral regurgitation (r = 0.87). Interobserver reproducibility for regurgitant volume and regurgitant fraction were excellent (r = 0.99, SEE = 238 ml; r = 0.98, SEE = 4.1%, respectively.) The authors concluded that these findings suggest that velocity-encoded NMR imaging can be used to estimate regurgitant volume and regurgitant fraction in patients with mitral regurgitation and can discriminate patients with moderate or severe mitral regurgitation from normal subjects and patients with mild regurgitation. Thus they believe it may be useful for monitoring the effect of therapy intended to reduce the severity of mitral regurgitation. Eichenberger et al. (1993) The purpose of this study was to determine the feasibility and accuracy of velocity-encoded cine MR for estimating pressure gradients across the aortic valve in patients with aortic stenosis. Pressure gradients across the aortic valve (AV) due to stenosis of the valve must be measured accurately to evaluate the functional severity of the stenosis. Velocity-encoded cine MR has been used to quantify blood flow and flow direction and, more recently, the regurgitant fraction in aortic regurgitation. The authors employed velocity-encoded cine MR to measure flow velocity and determine pressure gradients across the aortic valve in 19 subjects. The pressure gradient (delta P) was estimated from the simplified Bernoulli equation by using the maximum instantaneous aortic jet velocity (V max : ∆P (mm Hg) = 4V 2 max (m/sec). Maximum and mean systolic pressure gradients determined by using velocity-encoded cine MR were 3-148 mm Hg and 2-87 mm Hg, respectively, for all subjects. The pressure gradients correlated closely with gradients determined by using established methods: Doppler echocardiography and cardiac catheterization. Correlation coefficients (r) were .96 (y = 0.94x - 1.9) and .97 (y = 0.97x + 0.5), respectively. The authors concluded that velocity-encoded cine MR imaging provides a noninvasive and accurate means for quantifying the severity of valvular aortic stenosis. Honda (1993) Aortic regurgitation (AR) in five healthy volunteers and 26 patients (mean age, 60.3 years; range, 25-83 years) was quantitatively measured with magnetic resonance (MR) imaging velocity mapping. Cine transverse images of the ascending aorta (32 phases per cardiac cycle) were acquired by using a gradient-echo sequence with a velocity-encoding bipolar pulse applied in the section-selection direction with a 1.5-T MR imaging unit. Aortic flow was calculated by integrating the product of area and mean velocity of the ascending aorta at each phase over a cardiac cycle. The negative and positive velocity values indicated antegrade and regurgitant flow, respectively, which allowed calculation of forward and regurgitant flow. Inter- and intraobserver variation of regurgitant fraction (RF) measurement was small (r = .956, standard error of the estimate [SEE] = 1.2%, n = 31; and r = .998, SEE = 0.35%, n = 10, respectively). RF determined with MR imaging agreed well with Doppler echocardiographic (n = 26) and aortographic (n = 9) grading of AR. The authors conclude that reproducible, quantitative, and noninvasive measurement of AR is possible with MR velocity mapping. Kilner et al. (1993) The objective of this study was validation of MR jet velocity mapping in patients with cardiac valve stenosis. The authors used a 0.5-T Picker MR machine to measure peak poststenotic jet velocity in 15 consecutive patients recruited with known valve disease (six mitral stenosis, three of these restudied after valvuloplasty, and 11 aortic stenosis). On the same day as the MR study, these patients underwent independent Doppler echocardiographic measurement of peak jet velocity. The results of 10 further MR investigations of aortic stenosis are also reported and compared with Doppler studies performed within 6 months. To reiterate, of 26 patients 14-79 years old (mean age, 53 years), 15 were recruited prospectively for the study, being known to have mitral and/or aortic stenosis. Of these, five had mitral stenosis. A total of 29 MRI studies were performed, 28 (97%) produced interpretable velocity maps, the one failure being attributed to misplacement of the imaging slice in a case of severe aortic stenosis. Agreement between MR and Doppler measurements of peak jet velocity in the recruited group was as follows: n = 18; range, 1.4-6.1 m/sec; mean, 3 m/sec; mean of differences (MR-Doppler), 0.23 m/sec; standard deviation of differences, 0.49 m/sec. The authors concluded that in vivo MR peak jet velocity measurements agree well with those made by Doppler ultrasound. They also surmised that the technique, which is not subject to restricted windows of access and has potential for further refinements, could contribute to improved evaluation of stenoses, especially at locations where ultrasonic access is limited. Kizilbash et al. (1993) The authors compared quantitative Doppler echocardiography and cine magnetic resonance imaging for calculation of regurgitant volume and regurgitant fraction in mitral regurgitation. The study population consisted of 22 subjects (14 men and 8 women, 24 to 68 years of age) referred for echocardiography for evaluation of MR. In these patients, MR was associated with mitral valve prolapse (n = 9), dilated cardiomyopathy (n = 5), and ischemic heart disease (n 5 4). Forward stroke volume was measured by velocity encoded phase difference sequences positioned perpendicular to the ascending aorta, well above the aortic valve and coronary ostia. For flow sequences, slices of 10 mm thickness were obtained with a 256 3 192 matrix, 35-cm field-of-view, 60° flip angle, 460 to 500 ms repetition time, and 5 ms echo time. After
Codes in this policy
Code numbers and each code’s status as the policy records it. CPT code descriptions are left out of this page, as are the passages that cite CPT codes; the official document has them.
Backwork has no codes on record for this policy. Check the source.