About this policy
LCD Information
Document Information
Source LCD ID
N/A
LCD ID
L36427
Original ICD-9 LCD ID
Not Applicable
LCD Title
Wireless Capsule Endoscopy
Proposed LCD in Comment Period
N/A
Source Proposed LCD
DL36427 Opens in a new window
Original Effective Date
For services performed on or after 01/25/2016
Revision Effective Date
For services performed on or after 10/28/2021
Revision Ending Date
N/A
Retirement Date
N/A
Notice Period Start Date
04/20/2017
Notice Period End Date
06/04/2017
CPT codes, descriptions, and other data only are copyright 2025 American Medical Association. All Rights Reserved. Fee schedules, relative value units, conversion factors and/or related components are not assigned by the AMA, are not part of CPT, and the AMA is not recommending their use. The AMA does not directly or indirectly practice medicine or dispense medical services. The AMA assumes no liability for data contained or not contained herein. CPT is a registered trademark of the American Medical Association.
Current Dental Terminology © 2025 American Dental Association. All rights reserved.
Copyright © 2026, the American Hospital Association, Chicago, Illinois. Reproduced with permission.
No portion of the AHA copyrighted materials contained within this publication may be
copied without the express written consent of the AHA. AHA copyrighted materials including the UB‐04 codes and
descriptions may not be removed, copied, or utilized within any software, product, service, solution, or derivative work
without the written consent of the AHA. If an entity wishes to utilize any AHA materials, please contact the AHA at ub04@aha.org or 312‐422‐3366.
Making copies or utilizing the content of the UB‐04 Manual, including the codes and/or descriptions, for internal purposes,
resale and/or to be used in any product or publication; creating any modified or derivative work of the UB‐04 Manual and/or codes and descriptions;
and/or making any commercial use of UB‐04 Manual or any portion thereof, including the codes and/or descriptions, is only
authorized with an express license from the American Hospital Association.
The American Hospital Association (the "AHA") has not reviewed, and is not responsible for, the completeness or
accuracy of any information contained in this material, nor was the AHA or any of its affiliates, involved in the
preparation of this material, or the analysis of information provided in the material. The views and/or positions
presented in the material do not necessarily represent the views of the AHA. CMS and its products and services are
not endorsed by the AHA or any of its affiliates.
Issue
Issue Description
Issue - Explanation of Change Between Proposed LCD and Final LCD
CMS National Coverage Policy
Title XVIII of the Social Security Act, §1862(a)(1)(A) allows coverage and payment for only those services that are considered to be reasonable and necessary for the diagnosis or treatment of illness or injury or to improve the functioning of a malformed body member42 CFR 410.32(a) indicates that diagnostic tests may only be ordered by a treating physician (or other treating practitioner acting within the scope of his or her license and Medicare requirements)CMS Internet-Only Manual, Pub. 100-03, Medicare National Coverage Determinations Manual, Chapter 1, Part 2, §100.2 Endoscopy
Coverage Indications, Limitations, and/or Medical Necessity
Wireless capsule endoscopic imaging is intended as an adjunctive tool in the detection of certain gastrointestinal (GI) conditions. This procedure requires that a patient ingest a small capsule containing a disposable light source, miniature color video camera, battery, antenna and a data transmitter. The self-contained capsule is made of specially sealed biocompatible material that is resistant to the digestive fluids throughout the GI tract. Following ingestion of the capsule, natural contraction and relaxation of the GI tract propels the camera forward. The camera contained in the capsule records images of the intestinal mucosa as it travels the length of the digestive system. During the entire procedure, which normally takes approximately 8 hours, the patient wears a data recorder around the waist, which captures and stores the images transmitted by the capsule's camera. After completion of the procedure, the patient data recorder is connected to a computer workstation where the images are downloaded, reviewed, and interpreted by the physician. The capsule is designed to be disposable and is excreted naturally from the body.Indications for wireless capsule endoscopy:
• For investigating suspected small intestinal bleeding in persons with objective evidence of recurrent, obscure GI bleeding (e.g., persistent or recurrent iron-deficiency anemia and/or persistent or recurrent positive fecal occult blood test (FOBT), or visible bleeding) who have had upper and lower GI endoscopies within the past 12 months (esophagogastroduodenoscopy (EGD) and colonoscopy) that have failed to identify a bleeding source;• For evaluation of regional non-metastatic carcinoid tumors of the small bowel in persons with carcinoid syndrome;• For evaluation of persons with celiac disease with a positive serology and negative biopsy;• For re-evaluation of persons with celiac disease who remain symptomatic despite treatment and there is no suspected or confirmed GI obstruction, stricture, or fistulae;• For initial diagnosis in persons with suspected Crohn's disease (abdominal pain or diarrhea plus 1 or more signs of inflammation (e.g., fever, elevated white blood cell (WBC) count, elevated erythrocyte sedimentation rate, or bleeding) without evidence of disease on conventional diagnostic tests, including small-bowel follow-through or abdominal computed tomography (CT) scan/CT enterography and upper and lower endoscopy (EGD and colonoscopy);• For re-evaluation of persons with Crohn's disease who remain symptomatic despite treatment and there is no suspected or confirmed GI obstruction, stricture, or fistulae;• For surveillance of small intestinal tumors in persons with Lynch syndrome, Peutz-Jeghers syndrome and other polyposis syndromes affecting the small bowel; or • For screening or surveillance of esophageal varices.
Limitations of use:Wireless capsule endoscopy:
• is NOT indicated for repeat use to verify the effectiveness of surgery. • is NOT indicated for use as a screening test (other than esophageal varices) and is NOT reimbursable for colorectal cancer screening.• is NOT indicated for use as an initial test in diagnosing GI bleeding.• is NOT indicated for use for evaluating intussusception.• is NOT indicated for use for evaluating the colon, as it is not indicated for the confirmation of lesions of pathology normally within the reach of upper and lower endoscopes (lesions proximal to the ligament of Treitz, or distal to the ileum).• is NOT indicated for use for evaluating diseases involving the esophagus other than esophageal varices.• is NOT indicated for use for follow-up of persons with known small bowel disease other than Crohn's disease.• is NOT indicated for use in confirming pathology identified by other diagnostic means.• is NOT indicated for use in evaluating the stomach, as it is not indicated for the confirmation of lesions of pathology normally within the reach of upper and lower endoscopes (lesions proximal to the ligament of Treitz, or distal to the ileum).• is NOT indicated for use in investigating duodenal lymphocytosis, small bowel neoplasm, or suspected irritable bowel syndrome (IBS).
Wireless capsule endoscopy is covered only for services using United States (U.S.) Food and Drug Administration (FDA) approved devices and is not indicated for patients in whom a GI blockage is known or suspected, who have a significantly narrow small bowel, or have a known or suspected abnormal connection between the bowel and/or another organ (e.g., strictures or fistulas). An X-ray exam of the small bowel should be done if there is concern that it may be too narrow for the camera to pass through.Wireless capsule endoscopy should not be employed in patients with a cardiac pacemaker, or other implanted electromedical devices, or in patients who are pregnant.In addition to any specific limitations noted above, wireless capsule endoscopy is limited as follows:
• This test is only covered when performed by physicians trained in endoscopy or for independent diagnostic testing facilities (IDTF), which are under the general supervision of a physician trained in endoscopy procedures.• The capsule should be ingested at least 12 hours after the last meal, and the patient should not be allowed to eat for an additional 3 hours after the capsule is swallowed. Stool in the bowel may cause obstruction of images and result in failure of the study.
Medicare would not expect to see a second capsule administered per episode of illness unless it was to guarantee an adequate examination (e.g., the initial capsule does not penetrate the pylorus). Please note that any other procedures that are employed to ensure proper passage of the capsule must be reasonable and necessary and documented appropriately.Medicare expects repeat wireless capsule endoscopic studies for any patient to be for medically reasonable and necessary clinical circumstances consistent with accepted standards of medical practice and that the medical records demonstrate such.
Summary of Evidence
N/A
Analysis of Evidence (Rationale for Determination)
N/A
Coverage indications
Wireless capsule endoscopic imaging is intended as an adjunctive tool in the detection of certain gastrointestinal (GI) conditions. This procedure requires that a patient ingest a small capsule containing a disposable light source, miniature color video camera, battery, antenna and a data transmitter. The self-contained capsule is made of specially sealed biocompatible material that is resistant to the digestive fluids throughout the GI tract. Following ingestion of the capsule, natural contraction and relaxation of the GI tract propels the camera forward. The camera contained in the capsule records images of the intestinal mucosa as it travels the length of the digestive system. During the entire procedure, which normally takes approximately 8 hours, the patient wears a data recorder around the waist, which captures and stores the images transmitted by the capsule's camera. After completion of the procedure, the patient data recorder is connected to a computer workstation where the images are downloaded, reviewed, and interpreted by the physician. The capsule is designed to be disposable and is excreted naturally from the body. Indications for wireless capsule endoscopy: • For investigating suspected small intestinal bleeding in persons with objective evidence of recurrent, obscure GI bleeding (e.g., persistent or recurrent iron-deficiency anemia and/or persistent or recurrent positive fecal occult blood test (FOBT), or visible bleeding) who have had upper and lower GI endoscopies within the past 12 months (esophagogastroduodenoscopy (EGD) and colonoscopy) that have failed to identify a bleeding source; • For evaluation of regional non-metastatic carcinoid tumors of the small bowel in persons with carcinoid syndrome; • For evaluation of persons with celiac disease with a positive serology and negative biopsy; • For re-evaluation of persons with celiac disease who remain symptomatic despite treatment and there is no suspected or confirmed GI obstruction, stricture, or fistulae; • For initial diagnosis in persons with suspected Crohn's disease (abdominal pain or diarrhea plus 1 or more signs of inflammation (e.g., fever, elevated white blood cell (WBC) count, elevated erythrocyte sedimentation rate, or bleeding) without evidence of disease on conventional diagnostic tests, including small-bowel follow-through or abdominal computed tomography (CT) scan/CT enterography and upper and lower endoscopy (EGD and colonoscopy); • For re-evaluation of persons with Crohn's disease who remain symptomatic despite treatment and there is no suspected or confirmed GI obstruction, stricture, or fistulae; • For surveillance of small intestinal tumors in persons with Lynch syndrome, Peutz-Jeghers syndrome and other polyposis syndromes affecting the small bowel; or • For screening or surveillance of esophageal varices. Limitations of use: Wireless capsule endoscopy: • is NOT indicated for repeat use to verify the effectiveness of surgery. • is NOT indicated for use as a screening test (other than esophageal varices) and is NOT reimbursable for colorectal cancer screening. • is NOT indicated for use as an initial test in diagnosing GI bleeding. • is NOT indicated for use for evaluating intussusception. • is NOT indicated for use for evaluating the colon, as it is not indicated for the confirmation of lesions of pathology normally within the reach of upper and lower endoscopes (lesions proximal to the ligament of Treitz, or distal to the ileum). • is NOT indicated for use for evaluating diseases involving the esophagus other than esophageal varices. • is NOT indicated for use for follow-up of persons with known small bowel disease other than Crohn's disease. • is NOT indicated for use in confirming pathology identified by other diagnostic means. • is NOT indicated for use in evaluating the stomach, as it is not indicated for the confirmation of lesions of pathology normally within the reach of upper and lower endoscopes (lesions proximal to the ligament of Treitz, or distal to the ileum). • is NOT indicated for use in investigating duodenal lymphocytosis, small bowel neoplasm, or suspected irritable bowel syndrome (IBS). Wireless capsule endoscopy is covered only for services using United States (U.S.) Food and Drug Administration (FDA) approved devices and is not indicated for patients in whom a GI blockage is known or suspected, who have a significantly narrow small bowel, or have a known or suspected abnormal connection between the bowel and/or another organ (e.g., strictures or fistulas). An X-ray exam of the small bowel should be done if there is concern that it may be too narrow for the camera to pass through. Wireless capsule endoscopy should not be employed in patients with a cardiac pacemaker, or other implanted electromedical devices, or in patients who are pregnant. In addition to any specific limitations noted above, wireless capsule endoscopy is limited as follows: • This test is only covered when performed by physicians trained in endoscopy or for independent diagnostic testing facilities (IDTF), which are under the general supervision of a physician trained in endoscopy procedures. • The capsule should be ingested at least 12 hours after the last meal, and the patient should not be allowed to eat for an additional 3 hours after the capsule is swallowed. Stool in the bowel may cause obstruction of images and result in failure of the study. Medicare would not expect to see a second capsule administered per episode of illness unless it was to guarantee an adequate examination (e.g., the initial capsule does not penetrate the pylorus). Please note that any other procedures that are employed to ensure proper passage of the capsule must be reasonable and necessary and documented appropriately. Medicare expects repeat wireless capsule endoscopic studies for any patient to be for medically reasonable and necessary clinical circumstances consistent with accepted standards of medical practice and that the medical records demonstrate such.
Codes in this policy
Code numbers and each code’s status as the policy records it. CPT code descriptions are left out of this page, as are the passages that cite CPT codes; the official document has them.
Backwork has no codes on record for this policy. Check the source.