About this policy
LCD Information
Document Information
Source LCD ID
N/A
LCD ID
L36864
Original ICD-9 LCD ID
Not Applicable
LCD Title
GlycoMark® Testing for Glycemic Control
Proposed LCD in Comment Period
N/A
Source Proposed LCD
DL36864 Opens in a new window
Original Effective Date
For services performed on or after 08/01/2017
Revision Effective Date
For services performed on or after 10/16/2025
Revision Ending Date
N/A
Retirement Date
N/A
Notice Period Start Date
06/15/2017
Notice Period End Date
07/31/2017
CPT codes, descriptions, and other data only are copyright 2025 American Medical Association. All Rights Reserved. Fee schedules, relative value units, conversion factors and/or related components are not assigned by the AMA, are not part of CPT, and the AMA is not recommending their use. The AMA does not directly or indirectly practice medicine or dispense medical services. The AMA assumes no liability for data contained or not contained herein. CPT is a registered trademark of the American Medical Association.
Current Dental Terminology © 2025 American Dental Association. All rights reserved.
Copyright © 2026, the American Hospital Association, Chicago, Illinois. Reproduced with permission.
No portion of the AHA copyrighted materials contained within this publication may be
copied without the express written consent of the AHA. AHA copyrighted materials including the UB‐04 codes and
descriptions may not be removed, copied, or utilized within any software, product, service, solution, or derivative work
without the written consent of the AHA. If an entity wishes to utilize any AHA materials, please contact the AHA at ub04@aha.org or 312‐422‐3366.
Making copies or utilizing the content of the UB‐04 Manual, including the codes and/or descriptions, for internal purposes,
resale and/or to be used in any product or publication; creating any modified or derivative work of the UB‐04 Manual and/or codes and descriptions;
and/or making any commercial use of UB‐04 Manual or any portion thereof, including the codes and/or descriptions, is only
authorized with an express license from the American Hospital Association.
The American Hospital Association (the "AHA") has not reviewed, and is not responsible for, the completeness or
accuracy of any information contained in this material, nor was the AHA or any of its affiliates, involved in the
preparation of this material, or the analysis of information provided in the material. The views and/or positions
presented in the material do not necessarily represent the views of the AHA. CMS and its products and services are
not endorsed by the AHA or any of its affiliates.
Issue
Issue Description
This update is to consolidate JE and JF to have one unified document and policy number.
Issue - Explanation of Change Between Proposed LCD and Final LCD
CMS National Coverage Policy
Title XVIII of the Social Security Act, §1862(a)(1)(A) allows coverage and payment for only those services that are considered to be reasonable and necessary for the diagnosis or treatment of illness or injury or to improve the functioning of a malformed body member.42 CFR §410.32(a) indicates that diagnostic tests may be ordered by the treating physician (or other treating practitioner acting within the scope of his or her license and Medicare requirements).CMS Internet-Only Manual, Pub 100-02, Medicare Benefit Policy Manual, Chapter 15, §80 Requirements for Diagnostic X-Ray, Diagnostic Laboratory, and Other Diagnostic Tests, §80.1.1 Certification Changes, §80.1.2 A/B MAC (B) Contacts With Independent Clinical Laboratories.
Coverage Indications, Limitations, and/or Medical Necessity
This is a non-coverage policy for the GlycoMark® assay (aka 1,5-anhydroglucitol [1,5-AG]; developed by Nippon Kayaku, Co., Ltd).
Summary of Evidence
Current Diabetes TestingHemoglobin A1C measurement, reflecting hemoglobin glycation over the erythrocyte life span, is proportional to the mean glucose concentration over the preceding 2-3 months. A1C testing is recommended by the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD) consensus guideline for pharmacotherapy to control hyperglycemia in type 2 diabetes.1 In addition to A1C, fasting plasma glucose is used by patients and physicians to monitor diabetes. However, recent evidence strongly suggests that control of post-prandial hyperglycemia (PPG) may be necessary to achieve A1C targets <7%.2Several landmark clinical trials have convincingly demonstrated that individuals with diabetes are at increased risk of developing microvascular complications including retinopathy, nephropathy and neuropathy, as well as cardiovascular (CV) disease.3,4,5 The importance of tight glycemic control for protection against microvascular and CV disease in diabetes was established in the Diabetes Control and Complications Trial (DCCT)/Epidemiology of Diabetes Interventions and Complications (EDIC) study.6 The role of glycemic control on microvascular disease in type 2 diabetes was documented in the United Kingdom Prospective Diabetes Study (UKPDS).7 In addition, improving glycemic control improves microvascular outcomes, as illustrated by the findings of a meta-analysis of randomized trials (34,912 participants).8Considerable data indicates that elevated PPG levels, even in the absence of fasting hyperglycemia, increases the risk for CV disease.9,10,11 Numerous epidemiological studies have demonstrated a correlation between risk for CVD and both fasting and postprandial plasma glucose levels or A1C values.11 The United Kingdom Prospective Diabetes Study (UKPDS),3 the Diabetes Control and Complications Trial (DCCT),5 the Action to Control Cardiovascular Risk in Diabetes (ACCORD),12 and the Action in Diabetes and Vascular Disease: Preterax and Diamicron Modified Release Controlled Evaluation (ADVANCE)13 were landmark controlled clinical trials that evaluated the benefits of intensive glucose control on diabetes complications. Both the DCCT and UKPDS primary intervention studies also demonstrated long-term macrovascular benefits (>10 year follow-up).6,14 These studies illustrate that intensive glycemic control early in the course of diabetes is important in achieving CV benefit and provides guidance in terms of stratification of patients’ target glycemic control. The fact that postprandial glucose control is essential to optimize blood glucose levels has been confirmed by randomized controlled trials where therapeutic agents primarily target postprandial hyperglycemia.15,16,171,5-AG AssayMeasurement of serum 1,5-anhydroglucitol (1,5-AG) is thought to be a useful index of postprandial hyperglycemia, and is thought to be more robust than hemoglobin A1C (A1C) or fructosamine (used to evaluate glycemic control over 10-14 days).18,19 There is evidence that glycemic excursions, an aspect of diabetes control incompletely captured by A1C, may contribute to vascular damage independently of mean glucose concentration (A1C).20,21,22 Testing for 1,5-AG has been proposed to be an additional glycemic biomarker to assist clinicians in the management of glycemic control, particularly in patients with moderate to near-normal glycemic control to complement frequent self-monitoring or continuous monitoring of plasma glucose to confirm overall glycemic control.The 1,5-AG test measures the blood level of 1,5-anhydroglucitol, a compound that is ingested in food. Because the compound is not metabolized, a relatively constant blood level is maintained in individuals with blood glucose below 180 mg/dL via urinary excretion and reabsorption. In non-diabetic individuals, the rate of intake of 1,5-AG is matched by the daily excretion rate such that the serum levels and urinary excretion remain constant. When a diabetic’s blood glucose exceeds 180 mg/dL, 1,5-AG reabsorption is competitively blocked by glucose and the serum level of 1,5-AG falls. Serum 1,5-AG decreases until glucose level drops below 180 mg/dL when 1,5-AG reabsorption resumes a steady rate. In brief, 1,5-AG levels are inversely proportional to the degree of hyperglycemia.Proponents of serum 1,5-AG claim that testing reflects hyperglycemia over the past 2 weeks (inter-day excursions) and is recommended by the manufacturer for use in persons with diabetes and A1C <8% to help identify patients with frequent hyperglycemic excursions, and may be useful for estimating within-day glycemic excursion. They specify that serum 1,5-AG correlates with postprandial hyperglycemia in persons with diabetes and A1C <7% and is stated to be more strongly correlated with glucose variability as compared to A1C, fructosamine or glycated albumin over 2 to 3 days in persons with moderate glycemic control (A1C <8%). Data suggests that 1,5-AG is strongly inversely associated with A1C and fasting glucose in persons diagnosed with diabetes but is poorly correlated with fasting glucose and A1C in persons without diabetes. Multiple publications correlate various 1,5-AG end points with continuous glucose monitoring and show potentially improved correlation with glucose fluctuation and A1C in patients with diabetes and A1C <8% than other biomarkers.23,24,25,26,27,28 However, the number of studies and the quality of study correlations is poor. Appropriate clinical targets are unclear, as the strongest correlations are observed at the highest glucose concentrations, which suggests that the utility of 1,5-AG may primarily be limited to persons with overtly elevated glucose.
Analysis of Evidence (Rationale for Determination)
Level of Evidence:
Quality: Poor
Strength: Poor
Weight: Minimal
In summary, the data to support the use of this test is based on showing correlations over short periods with other early glycemic markers (A1C, fructosamine, or glycated albumin) but is not specific to the intended use population. Comparative studies do not show that 1,5-AG is as good as a 2-hour post prandial blood glucose, or alternative biomarker. At the current time, the relationship of 1,5-AG to long term diabetic complications in a patient with A1C <8% is unknown. Furthermore, no prospective studies have shown that managing 1,5-AG in patients with an A1C of 6.5-8% reduces micro- or macrovascular complications. In addition, there are no definitive guidelines for using alternative biomarkers as adjuncts to standard markers of glycemia, such as A1C, fasting glucose, or self-monitoring blood glucose measures. Long-term prospective studies are lacking, and large cohort studies are warranted to determine whether alternative biomarkers have potential utility for early diagnosis, management of diabetes, and prevention of diabetic complications.Due to the lack of clinical utility, 1,5-AG testing is not reasonable and necessary for the management of diabetes or the prevention of diabetic complications, and is not covered by Medicare.
Coverage indications
This is a non-coverage policy for the GlycoMark® assay (aka 1,5-anhydroglucitol [1,5-AG]; developed by Nippon Kayaku, Co., Ltd).
Codes in this policy
Code numbers and each code’s status as the policy records it. CPT code descriptions are left out of this page, as are the passages that cite CPT codes; the official document has them.
Backwork has no codes on record for this policy. Check the source.